Algeria Table 5
Values of Penalties Pq

Criteria Q Pq
Observed n/ observed

1. Minimal conditions on bracing lines

0

0.05

2. Redundancy in plan

0

0.05

3. Regularity in plan

0

0.05

4. Regularity in elevation

0

0.05

5. Control of material quality

0

0.05

6. Control of construction quality

0

0.10

 

 

Algeria Table 6
Weighting Coefficient β depending on Nature and Duration of Live Load

Case

Building Type

β

1

Residential use building, offices and assimilated

0.20

2

Buildings receiving the public temporarily:

- rooms of exhibition, of sport, places of cult, meeting rooms with stand up places 0.30
- classrooms, restaurants, dormitories, meeting rooms with sitting seats 0.40

3

Warehouses, hangars

0.50

4

Archives, libraries, tanks and assimilated buildings

1.00

5

Other buildings no aimed above

0.60