Table 3 Importance factor k4 of buildings in earthquake zones
Kind of building | Factor
k4 according to earthquake zones |
|||
1 | 2 | 3 | 4 | |
Apartment
build., with no greater gatherings of people to be expected (except high-rise build.), one-story factory or store houses, simple halls, buildings of minor importance |
0.75 | 0.80 | 0.85 | 0.90 |
Build.
with greater gatherings of people to be expected, especially high-rise build., schools, sports halls, churches, cinemas, concerthalls, theaters and similar build.; multi-story factory or store house build., wide-span halls |
0.80 | 0.85 | 0.90 | 0.95 |
Hospitals
and public infrastructural build. which should be able to carry out their tasks even after an earthquake; museums with valuable and unreplaceable collections |
0.85 | 0.90 | 0.95 | 1.00 |