Table Indonesia 1 

TYPE OF BUILDING

IMPORTANCE FACTOR I

  1. Monumental Buildings
  2. Essential facilities that should remain functional after an earthquake
    Examples of these facilities would be :
    Hospitals
    Food storage structures
    Emergency relief stores
    Power stations
    Water works
    Radio and Television facilities
    Places of assembly
  3. Distribution facilities for gas or petroleum products in urban areas
  4. Structures for the support or containment of dangerous substances (such as acids, toxic substances etc)
  5. Other structures

1.5

1.5

 

 

 

 

 

 

 

 

2.0


2.0

 

1.0