Table Macedonia 1
Building category |
Type of building or structure |
Building |
Out-of-category |
Buildings forming part of nuclear power stations; buildings for the transport and storage of inflammable liquids and gases; objects for the storage of toxic materials; more important telecommunications buildings and structures; buildings with more than 25 storeys, and other buildings upon whose unimpaired functioning depends the operation of other technical-technological systems, faults which could have disastrous effects on the environment and/or cause great material losses to the wider community; |
|
Category I |
Buildings which contain rooms for assembly use (cinemas, theatres, gymnasiums, exhibition-halls, etc.); university faculty buildings; schools; hospitals and health centres; fire stations; telecommunications buildings and structures not classified as out-of-category buildings (post-office, radio and television broadcasting, etc.); industrial buildings containing particularly valuable equipment; all energy-production buildings with power more then 40MW; buildings containing objects of exceptional cultural and artistic value, and other buildings in which activities of particular importance to socio-political communities are carried out. |
1.5 |
Category II |
Residential buildings; hotels; restaurants; public buildings not classified into Category I, industrial buildings not classified into Category I. |
1.0 |
Category III |
Auxiliary industrial buildings; agrotechnical buildings. |
0.75 |
Category IV |
Temporary buildings and structures whose collapse cannot endanger human lives. |
|