Table Romania 4
The
“Cw” seismic coefficient for non-structural
elements
Type of member |
Cw |
The direction of the seismic load “Sw” |
Non-structural walls |
ks |
normal to member surface |
Parapets, cantilever walls |
3 ks |
normal to member surface |
Suspended ceilings |
ks |
normal to member surface |
Internal and external ornaments, statues, low towers and chimneys |
4 ks |
any direction |
Cornices and other low importance cantilevers, tanks placed on buildings |
2.5 ks |
any direction |
The increasing factors of internal forces for members with stress concentration or reduced ductility
Type of member |
Efforts |
Joints between prefabricated elements with transmission of internal forces through welding |
1.5 |
Brick masonry or reinforced concrete structural walls, except their coupling beams (for shear force analysis) |
|
Floors over ground floor for stiff structures with flexible ground floor |
|
Abutment anchoring and fixing bolts |
2.0 |
Prestressed joints between reinforced concrete prefabricated elements |
|
Columns at the flexible level of stiff structures (columns of silo unit bottom cross-cut, columns supporting structural walls) |
3.0 |